| ⚙ Construction | ||
| Copper Construction | 1×1.24 mm | 1×0.0488″ |
| Insulation F | 1.80 mm | 0.0709″ |
| Protection PP | 4.76 mm | 0.1874″ |
| Armor | 6.35 mm | 0.25″ |
| 📐 Physical | ||
| Cable Diameter | 6.35 mm ± 0.10 mm | 0.25″ ± 0.0039″ |
| Cable Weight in Air | 167 kg/km | 112 lbs/kft |
| Cont. Temp Rating | 150 ℃ | 300 ℉ |
| 🔩 Mechanical | ||
| Cable Breaking Strength | 10 kN | 2250 lbs |
| Max. Suggested Working Tension | 5 kN | 1125 lbs |
| Min. Shave Diameter | 800 mm | 31.5″ |
| ⚡ Electrical | ||
| Voltage Rating | 1000 VDC | 1000 VDC |
| Insulation Resistance | 15000 MΩ·km | 50000 MΩ·kft |
| Resistance Typical | 18.1 Ω/km | 5.5 Ω/kft |
| Capacitance @ 1kHz | 92 pf/m | 28 pf/ft |
Frequently Asked Questions
Q
What is the maximum continuous temperature rating for this cable?
This cable has a continuous temperature rating of 150°C (300°F), making it suitable for high-temperature downhole environments commonly found in oil and gas well logging applications.
Q
What is the cable's breaking strength and recommended working tension?
The cable has a breaking strength of 10 kN (2,250 lbs). The maximum suggested working tension is 5 kN (1,125 lbs), which is 50% of the breaking strength — a standard safety margin for reliable field operations.
Q
What voltage rating does this cable support?
The cable is rated at 1000 VDC, suitable for powering downhole instruments and transmitting measurement signals in wireline logging and perforating operations.
Q
What is the insulation resistance of this cable?
The insulation resistance is 15,000 MΩ·km (50,000 MΩ·kft), indicating excellent electrical insulation integrity that minimizes signal leakage and ensures reliable data transmission in demanding downhole conditions.
Q
What is the minimum sheave diameter recommended for this cable?
The minimum sheave (drum/pulley) diameter is 800 mm (31.5″). Using sheaves smaller than this minimum may cause permanent deformation or damage to the cable's armor and insulation layers.
Q
What are the outer diameter and weight of this cable?
The cable has an outer diameter of 6.35 mm ± 0.10 mm (0.25″ ± 0.0039″) and weighs 167 kg/km (112 lbs/kft) in air. The compact diameter and controlled weight make it well-suited for standard wireline surface equipment and truck-mounted spooling systems.