Leave Your Message
G1FB-6.35 0.25 Single-Conductor 316L/825 Armor Logging Cable - China Suppliers Factory, 16 AWG TEC Cable
Hot Products

G1FB-6.35 0.25 Single-Conductor 316L/825 Armor Logging Cable - China Suppliers Factory, 16 AWG TEC Cable

Introducing the G1FB-6.35 logging cable, an exceptional product manufactured by leading suppliers in China. This single-conductor cable boasts an outer diameter of 6.35 mm, featuring a durable copper conductor and high-quality fluoroplastic insulation. Its seamless steel pipe armor ensures a waterproof and sealed structure, providing high tensile strength and excellent rigidity. Designed for general use, this heavy-duty logging cable is perfect for medium-temperature applications and is ideal for both medium and deep well logging. The G1FB-6.35 is specifically geared towards conventional oil and gas exploration and production logging, making it a reliable choice for industry professionals seeking durability and performance from a trusted factory in China

    Construction
    Copper Construction 1×1.24 mm 1×0.0488″
    Insulation F 1.80 mm 0.0709″
    Protection PP 4.76 mm 0.1874″
    Armor 6.35 mm 0.25″
    📐 Physical
    Cable Diameter 6.35 mm ± 0.10 mm 0.25″ ± 0.0039″
    Cable Weight in Air 167 kg/km 112 lbs/kft
    Cont. Temp Rating 150 ℃ 300 ℉
    🔩 Mechanical
    Cable Breaking Strength 10 kN 2250 lbs
    Max. Suggested Working Tension 5 kN 1125 lbs
    Min. Shave Diameter 800 mm 31.5″
    Electrical
    Voltage Rating 1000 VDC 1000 VDC
    Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
    Resistance Typical 18.1 Ω/km 5.5 Ω/kft
    Capacitance @ 1kHz 92 pf/m 28 pf/ft
    Frequently Asked Questions
    Q What is the maximum continuous temperature rating for this cable?
    This cable has a continuous temperature rating of 150°C (300°F), making it suitable for high-temperature downhole environments commonly found in oil and gas well logging applications.
    Q What is the cable's breaking strength and recommended working tension?
    The cable has a breaking strength of 10 kN (2,250 lbs). The maximum suggested working tension is 5 kN (1,125 lbs), which is 50% of the breaking strength — a standard safety margin for reliable field operations.
    Q What voltage rating does this cable support?
    The cable is rated at 1000 VDC, suitable for powering downhole instruments and transmitting measurement signals in wireline logging and perforating operations.
    Q What is the insulation resistance of this cable?
    The insulation resistance is 15,000 MΩ·km (50,000 MΩ·kft), indicating excellent electrical insulation integrity that minimizes signal leakage and ensures reliable data transmission in demanding downhole conditions.
    Q What is the minimum sheave diameter recommended for this cable?
    The minimum sheave (drum/pulley) diameter is 800 mm (31.5″). Using sheaves smaller than this minimum may cause permanent deformation or damage to the cable's armor and insulation layers.
    Q What are the outer diameter and weight of this cable?
    The cable has an outer diameter of 6.35 mm ± 0.10 mm (0.25″ ± 0.0039″) and weighs 167 kg/km (112 lbs/kft) in air. The compact diameter and controlled weight make it well-suited for standard wireline surface equipment and truck-mounted spooling systems.