Leave Your Message
GX-GG-2B1-2A1a-3.2  ( 1/8”), 3.2mm, 2 SM+2 MM, Optical Fiber
Fiber Optic Cable
Products Categories
Featured Products

GX-GG-2B1-2A1a-3.2 ( 1/8”), 3.2mm, 2 SM+2 MM, Optical Fiber

This is an optical fiber logging cable with a structure of 2B1 single-mode fiber and 2A1a multi-mode fiber, totaling 4 fibers, and an outer diameter of 3.2 mm. Used for DTS, DAS, DVS, High SpeedData Transmission, Real Time Monitoringwhile well intervention, VSP.

    Applicable Well Types:

    1. Conventional Oil & Gas Wells

    Adaptable Well Types: Medium-shallow vertical wells (depth ≤ 2500m), low-deviation directional wells (build-up section ≤ 45°), shallow cased wells (φ73mm/φ89mm thin-walled casing)

    Typical Applications: Shallow oil & gas exploration wells, daily monitoring of conventional production wells, supplementary logging operations for small-diameter cased wells.

    2. Unconventional Oil & Gas Wells

    Adaptable Well Types: Shallow coalbed methane wells (depth ≤ 1500m), shallow shale gas vertical wells/short-horizontal-section horizontal wells (horizontal section ≤ 500m)

    Typical Applications: Monitoring of shallow coalbed methane development wells, logging of shallow vertical wells in the exploration stage of shale gas.

    3. Other Exploration & Engineering Wells

    Adaptable Well Types: Shallow geothermal wells (bottomhole temperature ≤ 150℃, depth ≤ 2000m), hydrogeological exploration wells (small-diameter detection wells), small-diameter monitoring wells in underground coal mines

    Typical Applications:Exploration and monitoring of medium-temperature geothermal resources, collection of groundwater hydrological data, monitoring of gas control in underground coal mines.

    Strictly Inapplicable Scenarios

    1. Deep/ultra-deep wells (depth > 2500m): The 4kN breaking strength cannot withstand the total tension from the cable's own weight + tool weight, leading to high risk of cable breakage.

    2.High-deviation wells (> 45°)/long-horizontal-section horizontal wells (horizontal section > 500m): The 3.2mm small-diameter cable has limited torsion and friction resistance; it is prone to tangling and wear in high-deviation/long-horizontal sections, and the minimum bending diameter (320mm) cannot adapt to high build-up rate trajectories.

    3.Ultra-high temperature wells (bottomhole temperature > 150℃): Exceeding the rated temperature will cause aging of the cable protection layer and increased fiber signal attenuation, leading to monitoring failure.

    4.Highly corrosive wells (high H₂S/CO₂ concentration): No special corrosion-resistant customization; the conventional 316L stainless steel tube cannot withstand highly corrosive media for a long time, making armor rusting likely.

    5.Large-bore wells (wellbore diameter > 150mm): The small-diameter cable is prone to swinging and colliding with the wellbore in large-bore wells, resulting in insufficient protection performance and no adaptation advantage.

    Selection Reference

    Parameter

    Specification

    Applicable Well Condition

    Typical Well Type

    Fiber Configuration

    2 single-mode (B1) + 2 multi-mode (A1a)

    DTS/DAS signal transmission, bottomhole temp ≤150℃

    Shallow oil & gas wells, CBM wells

    Temperature Resistance

    Rated 150℃

    Medium-temperature, no ultra-high temp (>150℃)

    Medium-shallow geothermal wells

    Outer Diameter

    3.2mm, 316L stainless steel tube

    Wellbore diameter ≥80mm, slight corrosion

    Small-diameter cased wells

    Mechanical Performance

    Breaking strength 4kN, min bending 320mm

    Well depth ≤2500m, build-up ≤45°

    Low-deviation directional wells

    Send Inquiry