GX-GG-2B1-2A1a-6.35 PI ( 1/4”), 6.35mm, 2 SM+2 MM, 316L/A825 Armor Optical Fiber
Fiber Optic Cable
Products Categories
Featured Products

GX-GG-2B1-2A1a-6.35 PI ( 1/4”), 6.35mm, 2 SM+2 MM, 316L/A825 Armor Optical Fiber

This is an optical fiber logging cable with a structure of 2B1 single-mode fiber and 2A1a multi-mode fiber, totaling 4 fibers, and an outer diameter of 6.35 mm. It adopts Bare Fiber Coated with Polyimide, with a maximum operating temperature up to 300 ℃. Used for DTS, DAS, DVS, High Speed Data Transmission, Real Time Monitoring while well intervention, VSP.

    Applicable Well Types

    1. Conventional Oil & Gas Wells

    Adaptable Well Types: Deep vertical wells (depth ≤ 5000m), medium-deviation directional wells (build-up section ≤ 60°), deep cased wells, deep open-hole wells, high-temperature exploration wells.

    Typical Applications: High-temperature deep oil & gas exploration, production dynamic monitoring of high-temperature wells, deep open-hole logging, permanent downhole monitoring.

    2. Unconventional Oil & Gas Wells

    Adaptable Well Types: High-temperature shale gas long-radius horizontal wells (horizontal section ≤ 1000m), deep coalbed methane wells, high-temperature tight oil & gas wells.

    Typical Applications: High-temperature shale gas horizontal well monitoring, deep CBM well monitoring, tight oil & gas dynamic monitoring, high-temperature zone fracturing effect evaluation.

    3. Other Exploration & Engineering Wells

    Adaptable Well Types: Medium-deep high-temperature geothermal wells (bottomhole temperature ≤ 300℃), deep hydrogeological wells, high-temperature engineering monitoring wells.

    Typical Applications: High-temperature geothermal resource monitoring, deep hydrogeological detection, high-temperature downhole monitoring projects.

    Strictly Inapplicable Scenarios

    1.Ultra-deep wells (depth > 5000m): Exceeds mechanical bearing limit, high risk of breakage.

    2.High-deviation wells (> 60°) / short-radius horizontal wells (build-up rate > 12°/100ft): Cannot adapt to sharp bending, easy to cause fiber damage.

    3.Ultra-high temperature wells (> 300℃): Exceeds temperature resistance, leading to insulation failure and signal attenuation.

    4.Severe corrosion environment with ultra-high H₂S/CO₂: Long-term severe corrosion may damage the structure.

    5.Ultra-high pressure > 100MPa: Exceeds pressure rating, risk of seal failure.

    Selection Reference

    Parameter

    Specification

    Applicable Well Condition

    Typical Well Type

    Fiber Configuration

    2 single-mode (B1) + 2 multi-mode (A1a), 316L/A825 stainless steel fiber unit tube

    DTS/DAS signal transmission, bottomhole temperature ≤300℃, no heavy mechanical load, fiber reserve length >3‰, high-temperature stable signal transmission

    High-temperature deep conventional oil & gas wells, high-temperature shale gas wells, deep coalbed methane wells

    Temperature Resistance

    Rated temperature 300℃ (572℉), PI (polyimide) insulation layer, high-temperature resistance, no aging under 300℃ long-term operation

    High-temperature working conditions, bottomhole temperature ≤300℃, no ultra-high temperature (>300℃) environment, high-temperature downhole long-term monitoring

    High-temperature deep oil & gas wells, high-temperature geothermal wells, high-temperature unconventional oil & gas wells

    Protection & Outer Diameter

    Outer diameter 6.35mm±0.10mm, 316L/A825 stainless steel outer tube + PI encapsulation, corrosion-resistant, high-temperature resistant, pressure-resistant

    Wellbore diameter ≥80mm, moderate wellbore wear, corrosive formation fluid (H₂S/CO₂/Cl⁻), rated pressure ≤100MPa, high-temperature downhole environment

    Deep cased wells, deep open-hole wells, high-temperature corrosive oil & gas wells, high-temperature geothermal wells

    Mechanical Performance

    Breaking strength 10kN, maximum working tension 5kN, minimum bending diameter 800mm, good flexibility and torsion resistance, high-temperature mechanical stability

    Well depth ≤5000m, build-up section ≤60°, no sudden dogleg severity, horizontal section ≤1000m (long radius), high-temperature downhole tension and friction conditions

    Deep vertical wells, medium-deviation directional wells, high-temperature shale gas long-radius horizontal wells, deep coalbed methane wells