Construction |
| Copper Construction |
7*0.21 mm |
7*0.0082" |
| Insulation (PP) |
1.24 mm |
0.0488" |
| Number and Size of Wires |
|
|
| Inner Armor |
12*0.36 mm |
12*0.0141" |
| Outer Armor |
18*0.36 mm |
18*0.0141" |
| Average Wire Breaking Strength |
|
|
| Inner Armor |
190 N |
421 lbs |
| Outer Armor |
190 N |
421 lbs |
Physical |
| Cable Diameter |
2.56 mm+0.13 mm-0.05 mm |
0.1008"+0.0051"-0.0019" |
| Cable Weight in Air |
29 kg/km |
19 lbs/kft |
| 1 hr. Max Temp |
150 ℃ |
300 °F |
| 8 hr. Max Temp |
135 ℃ |
275 °F |
| Cont. Max Temp |
121 ℃ |
250 °F |
Mechanical |
| Cable Breaking Strength |
4 kN |
900 lbs |
| Maximum Suggested Working Tension |
2 kN |
450 lbs |
| Minimum Shave Diameter |
150 mm |
6.0" |
| Cable Stretch Coefficient |
14.7 m/km/5kN |
13.0 ft/kft/klbs |
ELECTRICAL |
| Voltage Rating |
300 VDC |
300 VDC |
| Insulation Resistance |
15000 MΩ·km |
50000 MΩ·kft |
| Resistance Typical@20 ℃ |
75 Ω/km |
22.8 Ω/kft |
| Capacitance@1kH |
167 pf/m |
51 pf/ft |