0102030405
1/4 6.35mm Monoconductor AWG 16 Copper Wire - China Suppliers and Factory Direct Offer
Construction Specifications
| Copper Construction | 19*0.30 mm | 19*0.0118" |
| Insulation (FEP) | 1.83mm | 0.0720" |
| Insulation (ETFE) | 2.51mm | 0.0988" |
| Inner Armor | 12*0.89mm | 12*0.0350" |
| Outer Armor | 18*0.89 mm | 18*0.0350" |
| Inner Armor Breaking Strength | 1162N | 261lbs |
| Outer Armor Breaking Strength | 1162N | 261lbs |
Physical Properties
| Cable Diameter | 6.35mm (+0.13/-0.05) | 0.250" (+0.0051/-0.0019) |
| Cable Weight in Air | 180/km | 120lbs/kft |
| 1 hr. Max Temp | 260℃ | 500°F |
| 8 hr. Max Temp | 232℃ | 450°F |
| Cont. Max Temp | 204℃ | 400°F |
Mechanical Performance
| Cable Breaking Strength | 30 kN | 6750lbs |
| Max Suggested Working Tension | 15 kN | 3370lbs |
| Minimum Sheave Diameter | 350 mm | 14" |
| Cable Stretch Coefficient | 2.5 m/km/5kN | 2.2 ft/kft/klbs |
Electrical Characteristics
| Voltage Rating | 1200 VDC | 1200 VDC |
| Insulation Resistance | 15000 MΩ·km | 50000 MΩ·kft |
| Resistance Typical @ 20 ℃ | 13.1 Ω/km | 13.1 Ω/kft |
| Capacitance @ 1kHz | 167 pf/m | 51 pf/ft |
Frequently Asked Questions
What is the maximum continuous temperature this cable can withstand?
The cable is rated for a continuous maximum temperature of 204℃ (400°F). It can handle short-term exposure up to 260℃ (500°F) for 1 hour.
What are the insulation materials used in this construction?
The cable utilizes a dual-layer insulation system consisting of FEP (Fluorinated Ethylene Propylene) with a diameter of 1.83mm and ETFE (Ethylene Tetrafluoroethylene) with a diameter of 2.51mm for enhanced thermal and chemical resistance.
What is the voltage rating and insulation resistance of the cable?
The cable is rated for 1200 VDC. It features a high insulation resistance of 15000 MΩ·km (50000 MΩ·kft) to ensure reliable electrical performance in demanding environments.
How much tension can this cable safely handle during operation?
While the cable has a breaking strength of 30 kN (6750 lbs), the maximum suggested working tension is 15 kN (3370 lbs) to maintain structural integrity and longevity.
What is the armor construction of this specific cable?
The cable features a double-armor design. The inner armor consists of 12 wires of 0.89mm, and the outer armor consists of 18 wires of 0.89mm, providing robust mechanical protection.
What is the stretch coefficient of the cable under load?
The cable stretch coefficient is 2.5 m/km/5kN (or 2.2 ft/kft/klbs), which is critical for calculating depth accuracy in downhole applications.













Durable FEP Insulation for Superior Protection