0102030405
China Suppliers G1FB-6.35 0.25 Single-Conductor 316L/825 Armor TEC Cable - Heavy Duty Logging Cable Factory Direct
| 🔩 Construction | ||
| Copper Construction | 1×1.24 mm | 1×0.0488″ |
| Insulation F | 1.80 mm | 0.0709″ |
| Protection PP | 4.76 mm | 0.1874″ |
| Armor | 6.35 mm | 0.25″ |
| 📐 Physical | ||
| Cable Diameter | 6.35 mm ± 0.10 mm | 0.25″ ± 0.0039″ |
| Cable Weight in Air | 167 kg/km | 112 lbs/kft |
| Cont. Temp Rating | 150 ℃ | 300 ℉ |
| ⚙️ Mechanical | ||
| Cable Breaking Strength | 10 kN | 2250 lbs |
| Max. Suggested Working Tension | 5 kN | 1125 lbs |
| Min. Shave Diameter | 800 mm | 31.5″ |
| ⚡ Electrical | ||
| Voltage Rating | 1000 VDC | 1000 VDC |
| Insulation Resistance | 15000 MΩ·km | 50000 MΩ·kft |
| Resistance Typical | 18.1 Ω/km | 5.5 Ω/kft |
| Capacitance @ 1kHz | 92 pf/m | 28 pf/ft |
❓ Frequently Asked Questions
💬
What is the maximum continuous temperature rating for this cable?
This cable has a continuous temperature rating of 150°C (300°F), making it suitable for high-temperature downhole environments commonly encountered in oil and gas well applications.
💬
What is the voltage rating of this armored cable?
The cable is rated at 1000 VDC, providing reliable electrical performance for submersible pump systems and downhole instrumentation operating at standard DC voltage levels.
💬
What is the cable breaking strength and recommended working tension?
The cable has a breaking strength of 10 kN (2250 lbs). The maximum suggested working tension is 5 kN (1125 lbs), which is 50% of the breaking strength — a standard safety factor for downhole cable deployment.
💬
What type of conductor is used in this cable construction?
The cable uses a single solid copper conductor with a diameter of 1.24 mm (0.0488″). Copper is chosen for its excellent electrical conductivity, flexibility, and corrosion resistance in demanding downhole conditions.
💬
What is the minimum shave diameter for this cable?
The minimum shave (sheave) diameter is 800 mm (31.5″). Maintaining this minimum bend radius during installation and deployment is critical to preventing mechanical damage to the armor and insulation layers.
💬
What is the insulation resistance value and why does it matter?
The insulation resistance is 15,000 MΩ·km (50,000 MΩ·kft) at rated conditions. A high insulation resistance value indicates excellent dielectric integrity, minimizing current leakage and ensuring safe, efficient signal or power transmission in downhole applications.