0102030405
GX-GG-2B1-2A1a-B 11×22 mm Fiber Optic Cable for Deep Well Logging - China Suppliers & Factory, 150℃ Rated, 70 kN Strength
| 🔩 Construction | ||
Armor Inner |
2.20 mm |
0.0886″ |
Outer |
4.0 mm |
0.157″ |
Steel Strand |
7×2.0 mm |
7×0.236″ |
Protection PP |
11×11 mm |
0.433″×0.866″ |
| 📐 Physical | ||
Cable Diameter |
11×22 mm ± 0.50 mm |
0.433″×0.866″ ± 0.0197″ |
Cable Weight in Air |
667 kg/km |
448 lbs/kft |
Temp Rating |
150 ℃ |
300 ℉ |
| ⚙️ Mechanical | ||
Cable Breaking Strength |
70 kN |
15,750 lbs |
Max. Suggested Working Tension |
35 kN |
7,875 lbs |
Min. Shave Diameter |
800 mm |
31.5″ |
| 📡 Attenuation | ||
Single-mode Fiber Decline @1310nm |
0.60 dB/km |
0.1828 dB/kft |
Single-mode Fiber Decline @1550nm |
0.40 dB/km |
0.1219 dB/kft |
Multi-mode Fiber Decline @850nm |
3.5 dB/km |
1.0668 dB/kft |
Multi-mode Fiber Decline @1300nm |
1.2 dB/km |
0.3658 dB/kft |
❓ Frequently Asked Questions
Q
What is the maximum operating temperature for this cable?
This cable is rated for a maximum temperature of 150°C (300°F), making it suitable for high-temperature downhole and industrial environments where standard cables may fail.
Q
What is the cable breaking strength and safe working tension?
The cable has a breaking strength of 70 kN (15,750 lbs). The maximum suggested working tension is 35 kN (7,875 lbs), which is 50% of the breaking strength to ensure a safe operating margin.
Q
What fiber types does this cable support, and what are their attenuation values?
The cable supports both single-mode and multi-mode fibers. Single-mode attenuation is 0.60 dB/km @1310nm and 0.40 dB/km @1550nm. Multi-mode attenuation is 3.5 dB/km @850nm and 1.2 dB/km @1300nm.
Q
What is the minimum shave diameter for this cable?
The minimum shave (sheave) diameter is 800 mm (31.5″). Using a sheave smaller than this minimum can cause mechanical stress on the cable, potentially damaging the armor or optical fibers inside.
Q
What is the outer cable diameter and weight in air?
The cable has an outer diameter of 11×22 mm (±0.50 mm), which is 0.433″×0.866″ (±0.0197″). Its weight in air is 667 kg/km (448 lbs/kft), important for calculating load capacity during deployment.
Q
What is the role of the steel strand and PP protection in the cable construction?
The 7×2.0 mm steel strand provides tensile strength and mechanical protection against pulling forces during installation and operation. The 11×11 mm PP (polypropylene) protection serves as an outer protective layer, shielding the cable from abrasion, moisture, and environmental damage.