Leave Your Message
7-Conductor 11.8mm Copper Wire - High-Quality FEP/ETFE Insulated Cable from China Suppliers and Factory
Hot Products

7-Conductor 11.8mm Copper Wire - High-Quality FEP/ETFE Insulated Cable from China Suppliers and Factory

,

15/32  11.8 mm

,

7-CONDUCTOR,AWG 20 

,

Copper  Copper Conductor for superior conductivity

,

FEP/ETFE    Durable FEP/ETFE Insulation ensuring long-lasting performance

,

Semi-conducting    Semi-conducting Shield Layer enhances signal integrity

,

Semi-conducting    Semi-conducting Filler for optimal dielectric performance

,

Additional    Additional Semi-conducting Shield Layer for improved shielding

,

Inner  Inner Armor Wires provide added protection

,

Outer  Outer Armor Wires enhance overall durability 

,

Our high-quality 7-conductor AWG 20 cable is manufactured in China, ensuring it meets strict industry standards. As a leading factory among suppliers, we provide exceptional products designed for reliability and performance in various applications. Choose us for top-notch cables that guarantee durability and efficiency.

,

    Parameter Metric Imperial
    Construction
    Copper Construction 7×0.32 mm 7×0.0126"
    Insulation (FEP) 2.48 mm 0.0976"
    Shield 2.50 mm 0.0988"
    Number and Size of Wires
    Inner Armor 24×1.00 mm 24×0.0389"
    Outer Armor 24×1.26 mm 24×0.0496"
    Average Wire Breaking Strength
    Inner Armor 2041 N 459 lbs
    Outer Armor 3240 N 729 lbs
    Physical
    Cable Diameter 11.80 mm +0.13 mm / −0.05 mm 0.4645" +0.0051" / −0.0019"
    Cable Weight in Air 509 kg/km 341 lbs/kft
    1 hr. Max Temp 260 ℃ 500 °F
    8 hr. Max Temp 232 ℃ 450 °F
    Cont. Max Temp 204 ℃ 400 °F
    Mechanical
    Cable Breaking Strength 117 kN 26,300 lbs
    Maximum Suggested Working Tension 58.5 kN 13,150 lbs
    Minimum Shave Diameter 600 mm 23.6"
    Cable Stretch Coefficient 0.8 m/km/5kN 0.714 ft/kft/klbs
    Electrical
    Voltage Rating 1000 VDC 1000 VDC
    Insulation Resistance 15,000 MΩ·km 50,000 MΩ·kft
    Resistance Typical @ 20 ℃ 33 Ω/km 10 Ω/kft
    Capacitance @ 1 kHz 130 pF/m 40 pF/ft
    ? Frequently Asked Questions
    Q1 What type of insulation is used in this cable, and why?
    This cable uses FEP (Fluorinated Ethylene Propylene) insulation with a diameter of 2.48 mm. FEP is chosen for its exceptional thermal resistance, supporting continuous operating temperatures up to 204 ℃ (400 °F), making it ideal for high-temperature downhole environments.
    Q2 What is the maximum working tension this cable can safely handle?
    The cable has a breaking strength of 117 kN (26,300 lbs). The maximum suggested working tension is 58.5 kN (13,150 lbs), which represents a 50% safety factor to ensure reliable and safe operation during deployment.
    Q3 What is the dual-armor construction and what does it provide?
    The cable features a dual-armor design: an inner armor of 24×1.00 mm wires (breaking strength 2,041 N / 459 lbs per wire) and an outer armor of 24×1.26 mm wires (3,240 N / 729 lbs per wire). This layered armor provides superior mechanical protection, crush resistance, and tensile strength for demanding well conditions.
    Q4 What are the temperature ratings for this cable?
    The cable supports three temperature ratings: a continuous maximum of 204 ℃ (400 °F), an 8-hour maximum of 232 ℃ (450 °F), and a 1-hour maximum of 260 ℃ (500 °F). These ratings allow flexibility for short-term high-temperature events while maintaining safety.
    Q5 What are the key electrical specifications of this cable?
    The cable is rated at 1,000 VDC with a typical conductor resistance of 33 Ω/km (10 Ω/kft) at 20 ℃. The insulation resistance is exceptionally high at 15,000 MΩ·km, and the capacitance at 1 kHz is 130 pF/m, ensuring reliable signal transmission in logging and monitoring applications.
    Q6 What is the minimum shave (sheave) diameter required for this cable?
    The minimum recommended sheave diameter is 600 mm (23.6"). Using a sheave smaller than this minimum can cause excessive bending stress on the armor wires and internal conductors, potentially reducing the service life or causing mechanical failure of the cable.