Leave Your Message
8.0 mm 5/16 Monoconductor AWG 15 Cable - China Suppliers & Factory with Copper Conductor and Stainless Steel Armor
Hot Products

8.0 mm 5/16 Monoconductor AWG 15 Cable - China Suppliers & Factory with Copper Conductor and Stainless Steel Armor

,

5/16  8.0 mm

,

MONOCONDUCTOR, AWG 15  

,

Copper  High-Quality Copper Conductor for Superior Performance

,

FEP   Durable FEP Insulation for Long-lasting Protection

,

ETFE   High-Performance ETFE Insulation for Enhanced Safety

,

Inner  Inner Armor Wires Made of Stainless Steel 316 for Added Strength

,

Outer  Outer Armor Wires Crafted from Stainless Steel 316 for Exceptional Durability

,

This product, made in our state-of-the-art factory in China, combines premium materials and advanced manufacturing techniques. As trusted suppliers, we ensure every component meets the highest standards, providing reliable and long-lasting solutions for your needs.

,

    Parameter Metric Imperial
    🔩 Construction
    Copper Construction 19 × 0.37 mm 19 × 0.0146"
    Insulation (FEP) 2.85 mm 0.1122"
    Insulation (ETFE) 3.81 mm 0.1496"
    Number and Size of Wires
    Inner Armor 12 × 1.11 mm 12 × 0.0437"
    Outer Armor 18 × 1.11 mm 18 × 0.0437"
    Average Wire Breaking Strength
    Inner Armor 1644 N 370 lbs
    Outer Armor 1644 N 370 lbs
    📐 Physical
    Cable Diameter 8.0 mm +0.13 / −0.05 mm 0.3150" +0.0051" / −0.0019"
    Cable Weight in Air 281 kg/km 189 lbs/kft
    1 hr. Max Temp 260 ℃ 500 °F
    8 hr. Max Temp 232 ℃ 450 °F
    Cont. Max Temp 204 ℃ 400 °F
    ⚙️ Mechanical
    Cable Breaking Strength 45 kN 10,125 lbs
    Maximum Suggested Working Tension 22.5 kN 5,062.5 lbs
    Minimum Shave Diameter 450 mm 18"
    Cable Stretch Coefficient 1.35 m/km/5kN 1.2 ft/kft/klbs
    Electrical
    Voltage Rating 1500 VDC 1500 VDC
    Insulation Resistance 15,000 MΩ·km 50,000 MΩ·kft
    Resistance Typical @ 20 ℃ 9.2 Ω/km 2.8 Ω/kft
    Capacitance @ 1 kHz 190 pF/m 58 pF/ft
    💬 Frequently Asked Questions
    What is the maximum continuous operating temperature of this cable?
    The cable supports a continuous maximum temperature of 204 ℃ (400 °F). For short-term exposure, it can withstand up to 260 ℃ (500 °F) for 1 hour, and 232 ℃ (450 °F) for up to 8 hours.
    What is the cable's breaking strength and recommended working tension?
    The cable has a total breaking strength of 45 kN (10,125 lbs). The maximum suggested working tension is 22.5 kN (5,062.5 lbs), which is 50% of the breaking strength to ensure a safe operating margin.
    What insulation materials are used, and what are their diameters?
    The cable uses two insulation material options: FEP (Fluorinated Ethylene Propylene) with a diameter of 2.85 mm (0.1122"), and ETFE (Ethylene Tetrafluoroethylene) with a diameter of 3.81 mm (0.1496"). Both materials offer excellent high-temperature and chemical resistance.
    What is the voltage rating and insulation resistance of the cable?
    The cable is rated at 1500 VDC. Its insulation resistance is exceptionally high at 15,000 MΩ·km (50,000 MΩ·kft), making it suitable for demanding downhole electrical applications where leakage must be minimized.
    What is the minimum shave (sheave) diameter for this cable?
    The minimum sheave diameter for this cable is 450 mm (18 inches). Using a sheave smaller than this minimum can cause mechanical damage to the armor wires and reduce the cable's service life.
    How is the armor construction designed, and what is each wire's breaking strength?
    The cable features a double-armor construction: an inner armor of 12 wires (each 1.11 mm / 0.0437") and an outer armor of 18 wires (each 1.11 mm / 0.0437"). Each individual armor wire has an average breaking strength of 1,644 N (370 lbs), providing robust mechanical protection for downhole deployment.