Leave Your Message
9/32 5.6mm AWG 15 Monoconductor Copper Wire with PP Insulation - China Factory Suppliers
Hot Products

9/32 5.6mm AWG 15 Monoconductor Copper Wire with PP Insulation - China Factory Suppliers

,

9/32  5.6 mm

,

MONOCONDUCTOR, AWG 15

,

Copper  High-Quality Copper Conductor

,

PP    Durable PP Insulation

,

Inner  Inner Armor Wires for Enhanced Protection

,

Outer  Outer Armor Wires for Maximum Durability

,

As a trusted China factory and leading suppliers of high-quality electrical components, we offer a robust solution with our 9/32 5.6 mm monoconductor wire. This AWG 15 wire ensures reliability with its premium copper conductor, durable PP insulation, and reinforced armor for both inner and outer layers. Choose our products for superior performance and enduring quality in all your electrical applications.

,

    Parameter Metric Imperial
    🔩 Construction
    Copper Construction 19 × 0.36 mm 19 × 0.0142"
    Insulation (PP) 2.63 mm 0.1035"
    Number and Size of Wires    
    Inner Armor 12 × 1.01 mm 12 × 0.0400"
    Outer Armor 18 × 1.01 mm 18 × 0.0400"
    Average Wire Breaking Strength    
    Inner Armor 1750 N 393 lbs
    Outer Armor 1750 N 393 lbs
    📐 Physical
    Cable Diameter 7.32 mm +0.13 / −0.05 mm 0.2882" +0.0051" / −0.0019"
    Cable Weight in Air 234 kg/km 157 lbs/kft
    1 hr. Max Temp 150 ℃ 300 °F
    8 hr. Max Temp 135 ℃ 275 °F
    Cont. Max Temp 121 ℃ 250 °F
    ⚙️ Mechanical
    Cable Breaking Strength 45.4 kN 10,200 lbs
    Maximum Suggested Working Tension 22.7 kN 5,100 lbs
    Minimum Shave Diameter 410 mm 16"
    Cable Stretch Coefficient 1.74 m/km/5kN 1.55 ft/kft/klbs
    ⚡ Electrical
    Voltage Rating 1500 VDC 1500 VDC
    Insulation Resistance 15,000 MΩ·km 50,000 MΩ·kft
    Resistance Typical @ 20 ℃ 9.2 Ω/km 2.8 Ω/kft
    Capacitance @ 1 kHz 220 pF/m 67 pF/ft
    ? Frequently Asked Questions
    Q What is the maximum continuous operating temperature of this cable?
    The cable is rated for a continuous maximum temperature of 121 ℃ (250 °F). For short-term exposure, it can handle up to 135 ℃ (275 °F) for 8 hours and 150 ℃ (300 °F) for 1 hour.
    Q What is the cable's breaking strength and recommended working tension?
    The cable has a breaking strength of 45.4 kN (10,200 lbs). The maximum suggested working tension is 22.7 kN (5,100 lbs), which is 50% of the breaking strength to ensure a safe operational margin.
    Q What voltage rating does this cable support?
    This cable supports a voltage rating of 1,500 VDC, making it suitable for high-voltage downhole and industrial applications that require reliable DC power transmission.
    Q What is the minimum shave (sheave) diameter for this cable?
    The minimum shave diameter is 410 mm (16 inches). Using a sheave smaller than this specification can cause mechanical damage to the armor wires and reduce the cable's service life.
    Q What type of insulation material is used, and what are its dimensions?
    The cable uses Polypropylene (PP) insulation with a diameter of 2.63 mm (0.1035"). PP insulation provides excellent chemical resistance, thermal stability, and electrical insulation performance for downhole environments.
    Q What are the insulation resistance and capacitance values of this cable?
    The insulation resistance is rated at 15,000 MΩ·km (50,000 MΩ·kft), indicating excellent dielectric integrity. The capacitance at 1 kHz is 220 pF/m (67 pF/ft), which is important for signal quality in measurement and telemetry applications.