Leave Your Message
China WGSF46F40-HS-7.32 Monoconductor Cable 9/32 7.32mm AWG 15 - Quality from Leading Suppliers and Factory
Hot Products

China WGSF46F40-HS-7.32 Monoconductor Cable 9/32 7.32mm AWG 15 - Quality from Leading Suppliers and Factory

,

9/32  7.32 mm

,

MONOCONDUCTOR, AWG 15

,

Copper  High-Quality Copper Conductor

,

FEP   Premium FEP Insulation for Enhanced Durability

,

ETFE   Advanced ETFE Insulation for Superior Performance

,

Inner  Robust Inner Armor Wires for Added Protection

,

Outer  Durable Outer Armor Wires for Maximum Strength

,

This product is manufactured by a leading factory in China, specializing in high-quality electrical components. As trusted suppliers, we ensure that our products meet rigorous international standards, offering reliability and performance for all your electrical needs.

,

    Parameter Metric Imperial
    Construction
    Copper Construction 19×0.36 mm 19×0.0141"
    Insulation FEP 2.15 mm 0.0842"
    Insulation ETFE 2.63 mm 0.1035"
    Number and Size of Wires
    Inner Armor 12×1.01 mm 12×0.0400"
    Outer Armor 18×1.01 mm 18×0.0400"
    Average Wire Breaking Strength
    Inner Armor 1750 N 393 lbs
    Outer Armor 1750 N 393 lbs
    Physical
    Cable Diameter 7.32 mm +0.13 / −0.05 mm 0.2882" +0.0051" / −0.0019"
    Cable Weight in Air 241 kg/km 162 lbs/kft
    1 hr. Max Temp 260 ℃ 500 °F
    8 hr. Max Temp 232 ℃ 450 °F
    Cont. Max Temp 204 ℃ 400 °F
    Mechanical
    Cable Breaking Strength 45.4 kN 10,200 lbs
    Maximum Suggested Working Tension 22.7 kN 5,100 lbs
    Minimum Shave Diameter 410 mm 16"
    Cable Stretch Coefficient 2.5 m/km/5kN 2.2 ft/kft/klbs
    Electrical
    Voltage Rating 1200 VDC 1200 VDC
    Insulation Resistance 15,000 MΩ·km 50,000 MΩ·kft
    Resistance Typical @ 20 ℃ 9.2 Ω/km 2.8 Ω/kft
    Capacitance @ 1 kHz 220 pF/m 67 pF/ft
    ? Frequently Asked Questions
    Q What is the maximum continuous operating temperature of this cable?
    The cable supports a continuous maximum temperature of 204 ℃ (400 °F). For short-duration operations, it can withstand up to 260 ℃ (500 °F) for 1 hour, or 232 ℃ (450 °F) for up to 8 hours.
    Q What is the cable's breaking strength and recommended working tension?
    The cable has a total breaking strength of 45.4 kN (10,200 lbs). The maximum suggested working tension is 22.7 kN (5,100 lbs), which is 50% of the breaking strength — a standard safety factor for downhole applications.
    Q What type of insulation is used, and what are the differences between FEP and ETFE?
    This cable offers two insulation options: FEP (fluorinated ethylene propylene) with a diameter of 2.15 mm, and ETFE (ethylene tetrafluoroethylene) with a slightly larger diameter of 2.63 mm. ETFE generally offers superior mechanical toughness, while FEP provides excellent chemical resistance and flexibility.
    Q What is the voltage rating and insulation resistance of this cable?
    The cable is rated at 1200 VDC. Its insulation resistance is exceptionally high at 15,000 MΩ·km (metric) or 50,000 MΩ·kft (imperial), making it well-suited for high-integrity downhole electrical transmission.
    Q What is the minimum shave (sheave) diameter for this cable?
    The minimum shave diameter is 410 mm (16 inches). Using a sheave smaller than this specification may cause permanent deformation of the armor wires or damage to the insulation, reducing cable service life.
    Q How is the copper conductor constructed, and what does the 19×0.36 mm specification mean?
    The copper conductor is a stranded design consisting of 19 individual wires, each with a diameter of 0.36 mm (0.0141"). This stranded construction provides greater flexibility compared to a solid conductor, which is critical for repeated spooling and deployment in wireline operations.