Leave Your Message
China 4-Conductor Copper Wire 4.7mm AWG 23 - Quality Suppliers & Factory Direct Product
Hot Products

China 4-Conductor Copper Wire 4.7mm AWG 23 - Quality Suppliers & Factory Direct Product

,

3/16 (4.7 mm) Premium Cable

,

4-CONDUCTOR, AWG 23

,

Copper  High-quality Copper Conductor for optimal performance

,

PP   Durable PP Insulation ensures long-lasting protection

,

Filler   Specialized Filler for enhanced stability

,

Protection   Robust Protection Layer for added durability

,

Inner  Inner Armor Wires for superior strength and resilience

,

Outer  Outer Armor Wires provide reliable protection

,

As a leading manufacturer in China, we take pride in supplying high-quality cables to meet diverse industrial needs. Our factory employs advanced technology and dedicated craftsmen to produce cables that excel in performance and safety. Choose us for dependable products that stand the test of time.

,

    👉 Scroll horizontally to view full table

    Parameter Metric Units Imperial Units
    🔩 Construction
    Copper Construction 7 × 0.21 mm 7 × 0.0082"
    Insulation (PP) 1.00 mm 0.0390"
    Protection 3.00 mm 0.1180"
    Number and Size of Wires
    Inner Armor 18 × 0.47 mm 18 × 0.0185"
    Outer Armor 18 × 0.64 mm 18 × 0.0251"
    Average Wire Breaking Strength
    Inner Armor 324 N 72.8 lbs
    Outer Armor 601 N 135 lbs
    📐 Physical
    Cable Diameter 4.70 mm +0.13 mm / −0.05 mm 0.1850" +0.0051" / −0.0019"
    Cable Weight in Air 85 kg/km 57.4 lbs/kft
    1 hr. Max Temp 150 ℃ 300 °F
    8 hr. Max Temp 135 ℃ 275 °F
    Cont. Max Temp 121 ℃ 250 °F
    ⚙️ Mechanical
    Cable Breaking Strength 13 kN 2900 lbs
    Maximum Suggested Working Tension 6.5 kN 1450 lbs
    Minimum Shave Diameter 260 mm 10.5"
    Cable Stretch Coefficient 4.78 m/km/5kN 4.25 ft/kft/klbs
    Electrical
    Voltage Rating 200 VDC 200 VDC
    Insulation Resistance 15,000 MΩ·km 50,000 MΩ·kft
    Resistance Typical @ 20 ℃ 75 Ω/km 22.7 Ω/kft
    Capacitance @ 1 kHz 190 pf/m 58 pf/ft
    💬 Frequently Asked Questions
    Q What is the maximum continuous operating temperature of this cable?
    The cable supports a continuous maximum temperature of 121 ℃ (250 °F). For short-duration applications, it can handle up to 135 ℃ (275 °F) for 8 hours and 150 ℃ (300 °F) for 1 hour.
    Q What is the cable's breaking strength and recommended working tension?
    The cable breaking strength is 13 kN (2,900 lbs). The maximum suggested working tension is 6.5 kN (1,450 lbs), which is 50% of the breaking strength — ensuring a safe operational margin during deployment.
    Q What type of conductor is used and how is it constructed?
    The conductor uses a 7-strand copper construction, with each strand measuring 0.21 mm (0.0082") in diameter. This stranded design provides flexibility and durability for wireline logging applications.
    Q What is the voltage rating and insulation resistance of this cable?
    The cable carries a voltage rating of 200 VDC. The insulation resistance is rated at 15,000 MΩ·km (50,000 MΩ·kft), providing excellent electrical isolation suitable for precision downhole measurement environments.
    Q What is the minimum sheave (shave) diameter recommended for this cable?
    The minimum sheave diameter is 260 mm (10.5"). Using a sheave smaller than this recommendation can cause excessive bending stress on the armor wires, leading to premature fatigue and reduced cable service life.
    Q How does the dual-armor construction benefit cable performance?
    The dual-armor design features an inner armor of 18 × 0.47 mm wires (breaking strength: 324 N / 72.8 lbs) and an outer armor of 18 × 0.64 mm wires (breaking strength: 601 N / 135 lbs). This layered armoring provides superior crush resistance, tensile strength, and protection against harsh downhole environments.