Leave Your Message
China 8.0 mm Monoconductor Cable AWG 15 - Suppliers for Copper Conductor, PP Insulation, and Armor Wires from Factory
Hot Products

China 8.0 mm Monoconductor Cable AWG 15 - Suppliers for Copper Conductor, PP Insulation, and Armor Wires from Factory

,

5/16  8.0 mm High-Quality Cable

,

MONOCONDUCTOR, AWG 15 for Reliable Connectivity

,

Copper  Durable Copper Conductor for Enhanced Performance

,

PP   PP Insulation for Superior Protection

,

Inner  Inner Armor Wires for Added Safety

,

Outer  Outer Armor Wires for Enhanced Durability 

,

As a leading supplier from China, our factory produces top-notch cables that meet international quality standards. With our 5/16  8.0 mm monoconductor design and AWG 15 specifications, you can trust in the reliability and efficiency of our products. The robust copper conductors and advanced insulation processes ensure long-lasting performance in any application.

,

    Parameter Metric Imperial
    Construction
    Copper Construction 19 × 0.37 mm 19 × 0.0146"
    Insulation (PP) 3.81 mm 0.1496"
    Number and Size of Wires
    Inner Armor 12 × 1.11 mm 12 × 0.0437"
    Outer Armor 18 × 1.11 mm 18 × 0.0437"
    Average Wire Breaking Strength
    Inner Armor 1970 N 442 lbs
    Outer Armor 1970 N 442 lbs
    Physical
    Cable Diameter 8.0 mm +0.13 / −0.05 mm 0.3150" +0.0051" / −0.0019"
    Cable Weight in Air 270 kg/km 184 lbs/kft
    1 hr. Max Temp 150 ℃ 300 °F
    8 hr. Max Temp 135 ℃ 275 °F
    Cont. Max Temp 121 ℃ 250 °F
    Mechanical
    Cable Breaking Strength 55 kN 12,300 lbs
    Maximum Suggested Working Tension 27.5 kN 6,150 lbs
    Minimum Shave Diameter 450 mm 18"
    Cable Stretch Coefficient 1.35 m/km/5kN 1.2 ft/kft/klbs
    Electrical
    Voltage Rating 1500 VDC 1500 VDC
    Insulation Resistance 15,000 MΩ·km 50,000 MΩ·kft
    Resistance Typical @ 20 ℃ 9.2 Ω/km 2.8 Ω/kft
    Capacitance @ 1 kHz 190 pF/m 58 pF/ft
    ? Frequently Asked Questions
    Q What is the maximum continuous operating temperature of this cable?
    The cable supports a continuous maximum temperature of 121 ℃ (250 °F). For short-term exposure, it can withstand up to 135 ℃ (275 °F) for 8 hours, and up to 150 ℃ (300 °F) for 1 hour, making it suitable for demanding downhole environments.
    Q What is the cable's breaking strength and recommended working tension?
    The cable has a total breaking strength of 55 kN (12,300 lbs). The maximum suggested working tension is 27.5 kN (6,150 lbs), which is 50% of the breaking strength, ensuring a safe operational safety factor during deployment.
    Q What voltage rating does this cable support?
    This cable is rated at 1500 VDC, with an insulation resistance of 15,000 MΩ·km (50,000 MΩ·kft), ensuring excellent electrical isolation and reliable signal or power transmission in high-voltage downhole applications.
    Q What are the armor construction details and their breaking strengths?
    The cable features a dual-armor design: the inner armor consists of 12 wires × 1.11 mm, and the outer armor consists of 18 wires × 1.11 mm. Both inner and outer armor wires have an average breaking strength of 1970 N (442 lbs) per wire, providing robust mechanical protection.
    Q What is the minimum sheave (pulley) diameter recommended for this cable?
    The minimum recommended sheave diameter is 450 mm (18 inches). Using sheaves smaller than this specification may cause excessive bending stress, potentially damaging the armor wires or the insulation and reducing the cable's service life.
    Q What is the conductor construction and its electrical resistance?
    The copper conductor is constructed with 19 strands × 0.37 mm wires, providing a flexible yet robust conductor. The typical DC resistance at 20 ℃ is 9.2 Ω/km (2.8 Ω/kft), and the capacitance is 190 pF/m (58 pF/ft) at 1 kHz, ensuring efficient electrical performance.