0102030405
High Quality 7-Conductor AWG 20 Cable with Copper Conductor - Leading China Factory Suppliers
| Construction | ||
| Copper Construction | 7 × 0.32 mm | 7 × 0.0126" |
| Insulation (PP) | 2.13 mm | 0.0838" |
| Number and Size of Wires | — | — |
| Inner Armor | 18 × 1.19 mm | 18 × 0.0468" |
| Outer Armor | 18 × 1.66 mm | 18 × 0.0653" |
| Average Wire Breaking Strength | — | — |
| Inner Armor | 2170 N | 488 lbs |
| Outer Armor | 4220 N | 948 lbs |
| Physical | ||
| Cable Diameter | 12.04 mm +0.13 mm / −0.05 mm | 0.4740" +0.0051" / −0.0019" |
| Cable Weight in Air | 550 kg/km | 370 lbs/kft |
| 1 hr. Max Temp | 150 ℃ | 300 °F |
| 8 hr. Max Temp | 135 ℃ | 275 °F |
| Cont. Max Temp | 121 ℃ | 250 °F |
| Mechanical | ||
| Cable Breaking Strength | 109 kN | 24,500 lbs |
| Maximum Suggested Working Tension | 54.5 kN | 12,250 lbs |
| Minimum Shave Diameter | 670 mm | 26.4" |
| Cable Stretch Coefficient | 0.69 m/km/5kN | 0.61 ft/kft/klbs |
| Electrical | ||
| Voltage Rating | 1200 VDC | 1200 VDC |
| Insulation Resistance | 15,000 MΩ·km | 50,000 MΩ·kft |
| Resistance Typical @ 20 ℃ | 33 Ω/km | 10 Ω/kft |
| Capacitance @ 1kHz | 160 pf/m | 48 pf/ft |
Frequently Asked Questions
Q
What is the maximum continuous operating temperature of this cable?
The cable is rated for a continuous maximum temperature of 121 ℃ (250 °F). For short-term operation, it can withstand up to 135 ℃ (275 °F) for 8 hours, and up to 150 ℃ (300 °F) for 1 hour.
Q
What is the cable breaking strength and recommended working tension?
The cable has a total breaking strength of 109 kN (24,500 lbs). The maximum suggested working tension is 54.5 kN (12,250 lbs), which is approximately 50% of the breaking strength — ensuring a safe safety factor during field operations.
Q
What voltage rating does this cable support?
This cable carries a voltage rating of 1200 VDC, making it suitable for high-voltage direct current downhole applications commonly used in oil and gas well logging operations.
Q
What is the insulation material and its resistance specification?
The insulation is made of Polypropylene (PP) with a diameter of 2.13 mm (0.0838"). The insulation resistance is rated at 15,000 MΩ·km (50,000 MΩ·kft), ensuring excellent electrical isolation under downhole conditions.
Q
What is the minimum sheave diameter required for this cable?
The minimum sheave (pulley) diameter for this cable is 670 mm (26.4"). Using a sheave smaller than this specification can cause mechanical damage to the cable armor and reduce its service life.
Q
What are the armor construction details and their breaking strengths?
The cable features a double-armor construction. The inner armor consists of 18 wires × 1.19 mm (0.0468") with an average wire breaking strength of 2,170 N (488 lbs). The outer armor consists of 18 wires × 1.66 mm (0.0653") with an average wire breaking strength of 4,220 N (948 lbs), providing robust mechanical protection for demanding downhole environments.