Leave Your Message
China Factory Suppliers for 1/10 2.56 mm AWG 24 Monoconductor Copper Cable with Armored Wires
Hot Products

China Factory Suppliers for 1/10 2.56 mm AWG 24 Monoconductor Copper Cable with Armored Wires

,

1/10 (2.56 mm)

,

MONOCONDUCTOR, AWG 24

,

Copper  Premium Copper Conductor

,

Inner  High-Quality Inner Armor Wires

,

PP  Durable PP Insulation

,

Outer  Strong Outer Armor Wires     

,

As a leading manufacturer in China, we specialize in high-quality AWG 24 monoconductor cables, designed to meet the needs of various applications. Our factory employs advanced technology and rigorous standards to produce reliable wiring solutions. Trust our products to deliver excellence, backed by years of experience as premier suppliers in the industry.

,

    Construction
    Copper Construction 7*0.21 mm 7*0.0082"
    Insulation (PP) 1.24 mm 0.0488"
    Number and Size of Wires    
    Inner Armor 12*0.36 mm 12*0.0141"
    Outer Armor 18*0.36 mm 18*0.0141"
    Average Wire Breaking Strength    
    Inner Armor 190 N 421 lbs
    Outer Armor 190 N 421 lbs
    Physical
    Cable Diameter 2.56 mm +0.13 mm −0.05 mm 0.1008" +0.0051" −0.0019"
    Cable Weight in Air 29 kg/km 19 lbs/kft
    1 hr. Max Temp 150 ℃ 300 °F
    8 hr. Max Temp 135 ℃ 275 °F
    Cont. Max Temp 121 ℃ 250 °F
    Mechanical
    Cable Breaking Strength 4 kN 900 lbs
    Maximum Suggested Working Tension 2 kN 450 lbs
    Minimum Shave Diameter 150 mm 6.0"
    Cable Stretch Coefficient 14.7 m/km/5kN 13.0 ft/kft/klbs
    Electrical
    Voltage Rating 300 VDC 300 VDC
    Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
    Resistance Typical @ 20 ℃ 75 Ω/km 22.8 Ω/kft
    Capacitance @ 1kHz 167 pF/m 51 pF/ft
    Frequently Asked Questions
    Q What is the maximum continuous operating temperature of this cable?
    The cable supports a continuous maximum temperature of 121 ℃ (250 °F). For short-duration high-heat scenarios, it can withstand up to 135 ℃ (275 °F) for 8 hours or 150 ℃ (300 °F) for 1 hour.
    Q What is the cable's breaking strength and recommended working tension?
    The cable has a breaking strength of 4 kN (900 lbs). The maximum suggested working tension is 2 kN (450 lbs), which is 50% of the breaking strength to ensure a reliable safety margin during operation.
    Q What voltage rating does this cable support?
    This cable is rated at 300 VDC. It also offers an insulation resistance of 15,000 MΩ·km (50,000 MΩ·kft), making it well-suited for low-voltage downhole instrumentation and data transmission applications.
    Q What is the minimum shave diameter for this cable?
    The minimum shave (sheave) diameter for this cable is 150 mm (6.0"). Using a sheave smaller than this minimum may result in damage to the armor wires or conductor and can reduce the cable's service life.
    Q What are the armor wire specifications for inner and outer layers?
    The inner armor consists of 12 wires at 0.36 mm (0.0141") diameter each, while the outer armor consists of 18 wires at the same 0.36 mm (0.0141") diameter. Both armor layers have an average wire breaking strength of 190 N (421 lbs).
    Q What is the cable's electrical resistance and capacitance?
    At 20 ℃, the typical conductor resistance is 75 Ω/km (22.8 Ω/kft). The capacitance measured at 1 kHz is 167 pF/m (51 pF/ft), which is an important parameter for signal integrity in wireline logging and telemetry systems.