0102030405
China WGSF46F40-HS-5.6 Monoconductor 7/32 AWG 16 Copper Wire | Suppliers & Factory Direct Product
| Parameter | Metric | Imperial |
| Construction | ||
| Copper Construction | 19×0.30 mm | 19×0.0118" |
| Insulation (FEP) | 2.14 mm | 0.0842" |
| Insulation (ETFE) | 2.76 mm | 0.1086" |
| Number and Size of Wires | — | — |
| Inner Armor | 15×0.61 mm | 15×0.0240" |
| Outer Armor | 15×0.89 mm | 15×0.0350" |
| Average Wire Breaking Strength | — | — |
| Inner Armor | 600 N | 135 lbs |
| Outer Armor | 1300 N | 292 lbs |
| Physical | ||
| Cable Diameter | 5.60 mm +0.13 mm / −0.05 mm | 0.2205" +0.0051" / −0.0019" |
| Cable Weight in Air | 145 kg/km | 97 lbs/kft |
| 1 hr. Max Temp | 260 ℃ | 500 °F |
| 8 hr. Max Temp | 232 ℃ | 450 °F |
| Cont. Max Temp | 204 ℃ | 400 °F |
| Mechanical | ||
| Cable Breaking Strength | 30 kN | 6700 lbs |
| Maximum Suggested Working Tension | 15 kN | 3300 lbs |
| Minimum Shave Diameter | 320 mm | 13" |
| Cable Stretch Coefficient | 2.5 m/km/5kN | 2.2 ft/kft/klbs |
| Electrical | ||
| Voltage Rating | 1200 VDC | 1200 VDC |
| Insulation Resistance | 15000 MΩ·km | 50000 MΩ·kft |
| Resistance Typical @ 20 ℃ | 13.1 Ω/km | 4.0 Ω/kft |
| Capacitance @ 1kHz | 220 pF/m | 67 pF/ft |
?
Frequently Asked Questions
Q
What is the maximum continuous operating temperature of this cable?
A
The cable supports a continuous maximum temperature of 204 ℃ (400 °F). For short-term exposure, it can withstand up to 260 ℃ (500 °F) for 1 hour, or 232 ℃ (450 °F) for up to 8 hours.
Q
What is the cable's breaking strength and recommended working tension?
A
The cable has a breaking strength of 30 kN (6700 lbs). The maximum suggested working tension is 15 kN (3300 lbs), which is 50% of the breaking strength to ensure a safe operating margin.
Q
What type of insulation materials are used in this cable?
A
This cable uses two high-performance fluoropolymer insulation options: FEP (Fluorinated Ethylene Propylene) with an outer diameter of 2.14 mm, and ETFE (Ethylene Tetrafluoroethylene) with an outer diameter of 2.76 mm. Both materials offer excellent chemical resistance and high-temperature performance.
Q
What is the voltage rating and insulation resistance of this cable?
A
The cable is rated at 1200 VDC. Its insulation resistance is 15,000 MΩ·km (50,000 MΩ·kft), indicating excellent electrical isolation suitable for demanding downhole or high-voltage environments.
Q
What is the minimum sheave (pulley) diameter recommended for this cable?
A
The minimum recommended sheave diameter is 320 mm (13 inches). Using a sheave smaller than this specification may cause mechanical stress, deformation, or premature failure of the cable armor and conductors.
Q
How is the copper conductor constructed in this cable?
A
The copper conductor consists of 19 individual strands, each 0.30 mm (0.0118") in diameter, stranded together to form a flexible and robust conductor. This multi-strand design enhances flexibility and fatigue resistance during repeated bending and deployment cycles.