| Parameter | Metric | Imperial |
| Construction | ||
| Copper Construction | 7×0.32 mm | 7×0.0126" |
| Insulation (PP) | 2.13 mm | 0.0838" |
| Number and Size of Wires | ||
| Inner Armor | 18×1.19 mm | 18×0.0468" |
| Outer Armor | 18×1.66 mm | 18×0.0653" |
| Average Wire Breaking Strength | ||
| Inner Armor | 2170 N | 488 lbs |
| Outer Armor | 4220 N | 948 lbs |
| Physical | ||
| Cable Diameter | 12.04 mm +0.13 / −0.05 mm | 0.4740" +0.0051" / −0.0019" |
| Cable Weight in Air | 550 kg/km | 370 lbs/kft |
| 1 hr. Max Temp | 150 ℃ | 300 °F |
| 8 hr. Max Temp | 135 ℃ | 275 °F |
| Cont. Max Temp | 121 ℃ | 250 °F |
| Mechanical | ||
| Cable Breaking Strength | 109 kN | 24,500 lbs |
| Maximum Suggested Working Tension | 54.5 kN | 12,250 lbs |
| Minimum Shave Diameter | 670 mm | 26.4" |
| Cable Stretch Coefficient | 0.69 m/km/5kN | 0.61 ft/kft/klbs |
| Electrical | ||
| Voltage Rating | 1200 VDC | 1200 VDC |
| Insulation Resistance | 15,000 MΩ·km | 50,000 MΩ·kft |
| Resistance Typical @ 20 ℃ | 33 Ω/km | 10 Ω/kft |
| Capacitance @ 1 kHz | 160 pF/m | 48 pF/ft |
FAQ Frequently Asked Questions
Q
What is the maximum continuous operating temperature of this cable?
The cable is rated for a continuous maximum temperature of 121 ℃ (250 °F). For short-term use, it can withstand up to 135 ℃ (275 °F) for 8 hours, and up to 150 ℃ (300 °F) for 1 hour.
Q
What is the cable breaking strength and recommended working tension?
The cable has a total breaking strength of 109 kN (24,500 lbs). The maximum suggested working tension is 54.5 kN (12,250 lbs), which is 50% of the breaking strength — a standard safety factor for downhole cable applications.
Q
What voltage rating does this cable support?
This cable carries a voltage rating of 1200 VDC, making it suitable for a wide range of downhole electrical submersible pump (ESP) and logging tool applications that operate within this voltage range.
Q
What type of insulation material is used, and what are its dimensions?
The cable uses Polypropylene (PP) insulation with a diameter of 2.13 mm (0.0838"). PP insulation offers excellent chemical resistance, thermal stability, and dielectric performance in harsh downhole environments.
Q
What is the minimum shave (sheave) diameter for this cable?
The minimum sheave diameter is 670 mm (26.4"). Using a sheave smaller than this specification may cause mechanical fatigue, kinking, or damage to the armor wires, which could compromise cable integrity and performance.
Q
What is the insulation resistance value and why does it matter?
The insulation resistance is rated at 15,000 MΩ·km (50,000 MΩ·kft). A high insulation resistance value is critical for downhole cables as it ensures minimal current leakage, protects connected instruments, and indicates the long-term dielectric integrity of the cable under high-pressure and high-temperature conditions.