| Parameter | Metric | Imperial |
|---|---|---|
| Construction | ||
| Fiber optic Unit Tube | 2.20 mm | 0.0866″ |
| Unit Tube Thickness | 0.25 mm | 0.0098″ |
| Outer Stainless Steel Tube | 6.35 mm | 0.25″ |
| Outer Tube Thickness | 0.71 mm | 0.0280″ |
| Physical | ||
| Cable Diameter | 6.35 mm ± 0.10 mm | 0.25″ ± 0.0039″ |
| Cable Weight in Air | 131 kg/km | 88 lbs/kft |
| Temp Rating | 300 ℃ | 572 ℉ |
| Mechanical | ||
| Cable Breaking Strength | 10 kN | 2250 lbs |
| Max. Suggested Working Tension | 5 kN | 1125 lbs |
| Min. Shave Diameter | 800 mm | 31.5″ |
| Attenuation | ||
| Single-mode Fiber Decline @ 1310 nm | 0.80 dB/km | 0.2438 dB/km |
| Single-mode Fiber Decline @ 1550 nm | 0.80 dB/km | 0.2438 dB/km |
| Multi-mode Fiber Decline @ 850 nm | 3.5 dB/km | 1.0668 dB/km |
| Multi-mode Fiber Decline @ 1300 nm | 1.5 dB/km | 0.4572 dB/km |
Frequently Asked Questions
Q
What is the maximum temperature rating of this fiber optic cable?
This fiber optic cable is rated for a maximum operating temperature of 300 °C (572 °F), making it suitable for high-temperature environments such as industrial facilities, downhole oil and gas applications, and other extreme thermal conditions.
Q
What is the cable breaking strength and recommended working tension?
The cable has a breaking strength of 10 kN (2,250 lbs). The maximum suggested working tension is 5 kN (1,125 lbs), which is 50% of the breaking strength, ensuring a safe operational margin during deployment and use.
Q
What fiber types are available and what are their attenuation values?
The cable supports both single-mode and multi-mode fibers. Single-mode fiber attenuation is 0.80 dB/km at both 1310 nm and 1550 nm. Multi-mode fiber attenuation is 3.5 dB/km at 850 nm and 1.5 dB/km at 1300 nm.
Q
What is the outer diameter and weight of the cable?
The cable has an outer diameter of 6.35 mm ± 0.10 mm (0.25″ ± 0.0039″) and weighs approximately 131 kg/km (88 lbs/kft) in air. Its compact size and manageable weight make it practical for long-run deployments.
Q
What is the minimum shave diameter for this cable?
The minimum shave (sheave) diameter for this cable is 800 mm (31.5″). Adhering to this minimum bend radius is essential to prevent mechanical damage to the fiber optic unit tube and maintain signal integrity during installation.
Q
What materials are used in the cable construction?
The cable features a 2.20 mm fiber optic unit tube with a 0.25 mm wall thickness, encased within a 6.35 mm outer stainless steel tube with a 0.71 mm wall thickness. The stainless steel outer tube provides robust mechanical protection, corrosion resistance, and structural integrity in harsh environments.