Construction |
| Copper Construction |
7*0.21 mm |
7*0.0082" |
| Insulation (PP) |
1.00mm |
0.0390" |
| Protection |
3.00mm |
0.1180" |
| Number and Size of Wires |
|
|
| Inner Armor |
18*0.47mm |
18*0.0185" |
| Outer Armor |
18*0.64 mm |
18*0.0251" |
| Average Wire Breaking Strength |
|
|
| Inner Armor |
324N |
72.8lbs |
| Outer Armor |
601N |
135lbs |
Physical |
| Cable Diameter |
4.70mm+0.13 mm-0.05 mm |
0.1850"+0.0051"-0.0019" |
| Cable Weight in Air |
85 /km |
57.4 lbs/kft |
| 1 hr. Max Temp |
150 ℃ |
300 °F |
| 8 hr. Max Temp |
135 ℃ |
275 °F |
| Cont. Max Temp |
121 ℃ |
250 °F |
Mechanical |
| Cable Breaking Strength |
13 kN |
2900 lbs |
| Maximum Suggested Working Tension |
6.5 kN |
1450 lbs |
| Minimum Shave Diameter |
260 mm |
10.5" |
| Cable Stretch Coefficient |
4.78 m/km/5kN |
4.25 ft/kft/klbs |
ELECTRICAL |
| Voltage Rating |
200 VDC |
200VDC |
| Insulation Resistance |
15000 MΩ·km |
50000 MΩ·kft |
| Resistance Typical@20 ℃ |
75 Ω/km |
22.7 Ω/kft |
| Capacitance@1kH |
190pf/m |
58 pf/ft |