Construction |
| Copper Construction |
7*0.36 mm |
7*0.0142" |
| Insulation (FEP&ETFE) |
2.48 mm |
0.0976" |
| Number and Size of Wires |
|
|
| Inner Armor |
22*1.11 mm |
22*0.0437" |
| Outer Armor |
22*1.44 mm |
22*0.0566" |
| Average Wire Breaking Strength |
|
|
| Inner Armor |
2272 N |
511 lbs |
| Outer Armor |
3825 N |
860 lbs |
Physical |
| Cable Diameter |
12.40 mm+0.13 mm-0.05 mm |
0.4882"+0.0051"-0.0019" |
| Cable Weight in Air |
580 kg/km |
390 lbs/kft |
| 1 hr. Max Temp |
260 ℃ |
500 °F |
| 8 hr. Max Temp |
232 ℃ |
450 °F |
| Cont. Max Temp |
204 ℃ |
400 °F |
Mechanical |
| Cable Breaking Strength |
125 kN |
28000 lbs |
| Maximum Suggested Working Tension |
62.5 kN |
14050 lbs |
| Minimum Shave Diameter |
600 mm |
23.6" |
| Cable Stretch Coefficient |
0.75 m/km/5kN |
0.67 ft/kft/klbs |
ELECTRICAL |
| Voltage Rating |
1200 VDC |
1200VDC |
| Insulation Resistance |
500 MΩ·km |
1640 MΩ·kft |
| Resistance Typical@20 ℃ |
26.5 Ω/km |
8.0 Ω/kft |
| Capacitance@1kH |
160 pf/m |
49 pf/ft |