0.490  12.4 mm

,

7-CONDUCTOR,AWG 19 

,

Copper  High-Quality Copper Conductor

,

FEP    Durable FEP Insulation

,

ETFE    Reliable ETFE Insulation

,

Protection    Enhanced Protection Features

,

Inner  Inner Armor Wires for Superior Coverage

,

Outer  Outer Armor Wires to Ensure Maximum Durability 

,

We are a leading supplier in China, providing premium-grade products from our advanced factory. Our cables are meticulously engineered to meet the highest standards, ensuring excellent performance and reliability in diverse applications.

,

    📋 Technical Specifications
    Parameter Metric Imperial
    🔧 Construction
    Copper Construction 7×0.36 mm 7×0.0142"
    Insulation (FEP & ETFE) 2.48 mm 0.0976"
    Number and Size of Wires    
    Inner Armor 22×1.11 mm 22×0.0437"
    Outer Armor 22×1.44 mm 22×0.0566"
    Average Wire Breaking Strength    
    Inner Armor 2514 N 565 lbs
    Outer Armor 4232 N 952 lbs
    📐 Physical
    Cable Diameter 12.40 mm +0.13 / −0.05 mm 0.4882" +0.0051" / −0.0019"
    Cable Weight in Air 580 kg/km 390 lbs/kft
    1 hr. Max Temp 260 ℃ 500 °F
    8 hr. Max Temp 232 ℃ 450 °F
    Cont. Max Temp 204 ℃ 400 °F
    ⚙️ Mechanical
    Cable Breaking Strength 140 kN 31,500 lbs
    Maximum Suggested Working Tension 70 kN 15,750 lbs
    Minimum Shave Diameter 576 mm 22.6"
    Cable Stretch Coefficient 0.8 m/km/5kN 0.714 ft/kft/klbs
    Electrical
    Voltage Rating 1200 VDC 1200 VDC
    Insulation Resistance 15,000 MΩ·km 50,000 MΩ·kft
    Resistance Typical @ 20 ℃ 26.5 Ω/km 8.0 Ω/kft
    Capacitance @ 1kHz 160 pF/m 49 pF/ft
    Frequently Asked Questions
    💬 What type of insulation material is used in this cable?
    This cable uses FEP (Fluorinated Ethylene Propylene) and ETFE (Ethylene Tetrafluoroethylene) as insulation materials. These high-performance fluoropolymers provide excellent chemical resistance, low friction, and outstanding thermal stability, making them ideal for demanding downhole environments.
    💬 What is the maximum operating temperature of this cable?
    The cable supports three temperature ratings depending on the duration of exposure: up to 260 °C (500 °F) for 1 hour, 232 °C (450 °F) for 8 hours, and a continuous maximum of 204 °C (400 °F). This tiered rating ensures safe operation across short-term and long-term thermal conditions.
    💬 What is the cable breaking strength and recommended working tension?
    The cable has a total breaking strength of 140 kN (31,500 lbs). For safe and reliable operation, the maximum suggested working tension is 70 kN (15,750 lbs), which represents a 2:1 safety factor over the breaking strength. Staying within this limit helps prevent mechanical fatigue and ensures long service life.
    💬 What is the voltage rating and insulation resistance of this cable?
    The cable is rated at 1200 VDC. It features an extremely high insulation resistance of 15,000 MΩ·km (50,000 MΩ·kft), which ensures minimal electrical leakage and excellent signal integrity even under high-temperature and high-pressure downhole conditions.
    💬 How is the armor construction designed and what are its breaking strengths?
    The cable features a dual-armor design. The inner armor consists of 22 wires of 1.11 mm diameter, with an average breaking strength of 2,514 N (565 lbs) per wire. The outer armor uses 22 wires of 1.44 mm diameter, providing a higher breaking strength of 4,232 N (952 lbs) per wire. This layered design offers superior mechanical protection and tensile strength.
    💬 What is the minimum shave diameter and why does it matter?
    The minimum shave (sheave) diameter for this cable is 576 mm (22.6 inches). This specification is critical during installation and retrieval operations — using a sheave smaller than the recommended diameter can induce excessive bending stress on the armor wires and conductors, potentially leading to premature failure or reduced cable lifespan.