0102030405
High-Quality 7-Conductor Copper Cable 15/32 11.8mm - China Suppliers & Factory Direct Supply
| Parameter | Metric | Imperial |
| Construction | ||
| Copper Construction | 7×0.33 mm | 7×0.0129" |
| Insulation (FEP) | 2.48 mm | 0.0976" |
| Shield | 2.50 mm | 0.0988" |
| Number and Size of Wires | — | — |
| Inner Armor | 24×1.00 mm | 24×0.0389" |
| Outer Armor | 24×1.26 mm | 24×0.0496" |
| Average Wire Breaking Strength | — | — |
| Inner Armor | 1,696 N | 382 lbs |
| Outer Armor | 2,692 N | 606 lbs |
| Physical | ||
| Cable Diameter | 11.80 mm +0.13 / −0.05 mm | 0.4645" +0.0051" / −0.0019" |
| Cable Weight in Air | 509 kg/km | 341 lbs/kft |
| 1 hr. Max Temp | 232 ℃ | 450 °F |
| 8 hr. Max Temp | 216 ℃ | 421 °F |
| Cont. Max Temp | 200 ℃ | 392 °F |
| Mechanical | ||
| Cable Breaking Strength | 100 kN | 22,500 lbs |
| Maximum Suggested Working Tension | 50 kN | 11,250 lbs |
| Minimum Shave Diameter | 504 mm | 20" |
| Cable Stretch Coefficient | 0.8 m/km/5kN | 0.714 ft/kft/klbs |
| Electrical | ||
| Voltage Rating | 1200 VDC | 1200 VDC |
| Insulation Resistance | 15,000 MΩ·km | 50,000 MΩ·kft |
| Resistance Typical @ 20 ℃ | 33 Ω/km | 10 Ω/kft |
| Capacitance @ 1 kHz | 130 pF/m | 40 pF/ft |
?
Frequently Asked Questions
Q
What type of insulation material is used in this cable, and why is FEP chosen?
This cable uses FEP (Fluorinated Ethylene Propylene) insulation with a diameter of 2.48 mm. FEP is selected for its excellent thermal stability, low dielectric constant, and resistance to harsh chemical environments — making it ideal for high-temperature downhole applications where continuous exposure to fluids and heat is expected.
Q
What is the maximum temperature this cable can withstand during continuous operation?
The cable is rated for a continuous maximum temperature of 200 ℃ (392 °F). For short-duration exposures, it can handle up to 216 ℃ (421 °F) for 8 hours and up to 232 ℃ (450 °F) for 1 hour, providing flexibility for varying downhole thermal conditions.
Q
What is the cable breaking strength and recommended working tension?
The cable has a total breaking strength of 100 kN (22,500 lbs). The maximum suggested working tension is 50 kN (11,250 lbs), which represents 50% of the breaking strength — a standard safety margin applied in oil and gas well intervention operations to prevent mechanical failure during deployment and retrieval.
Q
What is the voltage rating and insulation resistance of this cable?
The cable is rated at 1200 VDC with an insulation resistance of 15,000 MΩ·km (50,000 MΩ·kft). These electrical characteristics ensure reliable signal and power transmission in downhole logging tools while maintaining safe isolation in high-pressure, high-temperature well environments.
Q
What is the difference between the inner armor and outer armor in terms of strength?
The inner armor consists of 24 wires at 1.00 mm diameter, each with an average breaking strength of 1,696 N (382 lbs). The outer armor uses 24 wires at 1.26 mm diameter, providing a higher breaking strength of 2,692 N (606 lbs) per wire. The dual-armor design distributes mechanical load and provides enhanced protection against abrasion and crushing in demanding wellbore conditions.
Q
What is the minimum shave (sheave) diameter required for this cable and why does it matter?
The minimum sheave diameter for this cable is 504 mm (20"). Using a sheave smaller than this specification can cause excessive bending stress on the armor wires and copper conductors, leading to premature fatigue, micro-fractures, or complete cable failure. Always ensure that surface and downhole equipment sheaves meet or exceed this minimum diameter requirement.