8.0 mm 3-Conductor Copper Cable - China Suppliers Factory Direct W3BP-8.0
| Construction | ||
| Copper Construction | 7 × 0.32 mm | 7 × 0.0129" |
| Insulation (PP) | 1.86 mm | 0.0732" |
| Number and Size of Wires | ||
| Inner Armor | 18 × 0.81 mm | 18 × 0.0319" |
| Outer Armor | 18 × 1.11 mm | 18 × 0.0437" |
| Average Wire Breaking Strength | ||
| Inner Armor | 963 N | 216 lbs |
| Outer Armor | 1808 N | 406 lbs |
| Physical | ||
| Cable Diameter | 8.0 mm +0.13 / −0.05 mm | 0.3150" +0.0051" / −0.0019" |
| Cable Weight in Air | 255 g/km | 171 lbs/kft |
| 1 hr. Max Temp | 150 ℃ | 300 °F |
| 8 hr. Max Temp | 135 ℃ | 275 °F |
| Cont. Max Temp | 121 ℃ | 250 °F |
| Mechanical | ||
| Cable Breaking Strength | 45 kN | 10,100 lbs |
| Maximum Suggested Working Tension | 22.5 kN | 5,050 lbs |
| Minimum Shave Diameter | 450 mm | 18" |
| Cable Stretch Coefficient | 1.35 m/km/5kN | 1.2 ft/kft/klbs |
| Electrical | ||
| Voltage Rating | 1000 VDC | 1000 VDC |
| Insulation Resistance | 15,000 MΩ·km | 50,000 MΩ·kft |
| Resistance Typical @ 20 ℃ | 33 Ω/km | 10 Ω/kft |
| Capacitance @ 1 kHz | 175 pF/m | 53 pF/ft |
Frequently Asked Questions
Q
What is the maximum continuous operating temperature of this cable?
The cable supports a continuous maximum temperature of 121 ℃ (250 °F). For short-duration operations, it can withstand up to 135 ℃ (275 °F) for 8 hours and up to 150 ℃ (300 °F) for 1 hour.
Q
What is the cable breaking strength and recommended working tension?
The cable has a breaking strength of 45 kN (10,100 lbs). The maximum suggested working tension is 22.5 kN (5,050 lbs), which is 50% of the breaking strength to ensure a safe operational margin.
Q
What voltage rating does this cable support?
This cable is rated at 1000 VDC, making it suitable for a wide range of downhole and industrial electrical applications requiring reliable DC power transmission.
Q
What is the insulation material and its outer diameter?
The cable uses Polypropylene (PP) insulation with a diameter of 1.86 mm (0.0732"). The overall cable diameter is 8.0 mm (+0.13 / −0.05 mm), providing a compact yet robust profile.
Q
What is the minimum sheave diameter required for this cable?
The minimum sheave (pulley) diameter for this cable is 450 mm (18"). Using a sheave smaller than this minimum may cause mechanical stress, reduce cable lifespan, or lead to structural damage.
Q
What are the electrical resistance and capacitance values of this cable?
At 20 ℃, the typical conductor resistance is 33 Ω/km (10 Ω/kft). The capacitance at 1 kHz is 175 pF/m (53 pF/ft), and the insulation resistance is rated at 15,000 MΩ·km (50,000 MΩ·kft), indicating excellent insulation quality.