Leave Your Message
China Monoconductor 5.6mm Cable AWG 15 with Copper Conductor - Reliable Suppliers from Factory
Hot Products

China Monoconductor 5.6mm Cable AWG 15 with Copper Conductor - Reliable Suppliers from Factory

,

9/32  5.6 mm

,

MONOCONDUCTOR, AWG 15

,

Copper  Premium Copper Conductor

,

PP    Durable PP Insulation

,

Inner  Robust Inner Armor Wires

,

Outer  Reliable Outer Armor Wires 

,

As a leading China supplier and manufacturer, our factory produces high-quality wires featuring a 9/32 (5.6 mm) diameter and a monoconductor design with AWG 15 specifications. The wires are designed with premium copper conductors and durable PP insulation, ensuring excellent conductivity and safety in various applications. The incorporation of robust inner and reliable outer armor wires provides additional protection and durability. Trust our products for superior performance and durability.

,

    Parameter Metric Units Imperial Units
    Construction
    Copper Construction 19*0.36 mm 19*0.0142"
    Insulation (PP) 2.63 mm 0.1035"
    Number and Size of Wires    
    Inner Armor 12*1.01 mm 12*0.0400"
    Outer Armor 18*1.01 mm 18*0.0400"
    Average Wire Breaking Strength    
    Inner Armor 1750 N 393 lbs
    Outer Armor 1750 N 393 lbs
    Physical
    Cable Diameter 7.32 mm +0.13 mm / −0.05 mm 0.2882" +0.0051" / −0.0019"
    Cable Weight in Air 234 kg/km 157 lbs/kft
    1 hr. Max Temp 150 ℃ 300 °F
    8 hr. Max Temp 135 ℃ 275 °F
    Cont. Max Temp 121 ℃ 250 °F
    Mechanical
    Cable Breaking Strength 45.4 kN 10200 lbs
    Maximum Suggested Working Tension 22.7 kN 5100 lbs
    Minimum Shave Diameter 410 mm 16"
    Cable Stretch Coefficient 1.74 m/km/5kN 1.55 ft/kft/klbs
    Electrical
    Voltage Rating 1500 VDC 1500 VDC
    Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
    Resistance Typical @ 20 ℃ 9.2 Ω/km 2.8 Ω/kft
    Capacitance @ 1kHz 220 pF/m 67 pF/ft
    Frequently Asked Questions
    What is the voltage rating of this cable?
    This cable has a voltage rating of 1500 VDC, making it suitable for high-voltage downhole applications in both oil and gas well logging operations.
    What is the maximum operating temperature for continuous use?
    The cable supports a continuous maximum temperature of 121 °C (250 °F). For short-term exposure, it can handle up to 135 °C (275 °F) for 8 hours and 150 °C (300 °F) for 1 hour.
    What is the cable breaking strength and recommended working tension?
    The cable has a breaking strength of 45.4 kN (10,200 lbs). The maximum suggested working tension is 22.7 kN (5,100 lbs), which is 50% of the breaking strength to ensure safe and reliable operation.
    What type of armor construction does this cable use?
    The cable features a double armor construction: an inner armor of 12 wires × 1.01 mm and an outer armor of 18 wires × 1.01 mm. Each armor layer has an average wire breaking strength of 1,750 N (393 lbs).
    What is the insulation material and its outer diameter?
    The cable uses Polypropylene (PP) as the insulation material, with an insulated outer diameter of 2.63 mm (0.1035"). PP insulation provides excellent dielectric properties and thermal resistance for downhole environments.
    What is the minimum sheave diameter required for this cable?
    The minimum sheave (pulley) diameter for this cable is 410 mm (16 inches). Using a sheave smaller than this recommendation may cause permanent deformation or damage to the cable structure and armor wires.