Discover our top-of-the-line AWG 16 monoconductor cables with a diameter of 7/32 (5.6 mm). Manufactured in China, our cables feature superior copper conductors and durable PP insulation, ensuring optimal performance and longevity. The robust inner and outer armor wires provide additional protection, making them ideal for various applications. Trust our factory as a reliable supplier for your cable needs, offering unparalleled quality at competitive prices.

,

    Parameter Metric Imperial
    Construction
    Copper Construction 19×0.30 mm 19×0.0118"
    Insulation (PP) 2.15 mm 0.0846"
    Number and Size of Wires    
    Inner Armor 15×0.61 mm 15×0.0240"
    Outer Armor 15×0.89 mm 15×0.0350"
    Average Wire Breaking Strength    
    Inner Armor 600 N 135 lbs
    Outer Armor 1300 N 292 lbs
    Physical
    Cable Diameter 5.60 mm +0.13 mm / -0.05 mm 0.2205" +0.0051" / -0.0019"
    Cable Weight in Air 142 kg/km 96 lbs/kft
    1 hr. Max Temp 150 ℃ 300 °F
    8 hr. Max Temp 135 ℃ 275 °F
    Cont. Max Temp 121 ℃ 250 °F
    Mechanical
    Cable Breaking Strength 30 kN 6700 lbs
    Maximum Suggested Working Tension 15 kN 3350 lbs
    Minimum Shave Diameter 320 mm 13"
    Cable Stretch Coefficient 2.5 m/km/5kN 2.2 ft/kft/klbs
    Electrical
    Voltage Rating 1200 VDC 1200 VDC
    Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
    Resistance Typical @ 20 ℃ 13.1 Ω/km 4.0 Ω/kft
    Capacitance @ 1kHz 220 pF/m 67 pF/ft
    ? Frequently Asked Questions
    Q What is the maximum continuous operating temperature of this cable?
    The cable is rated for a maximum continuous operating temperature of 121 ℃ (250 °F). For short-term use, it can withstand up to 135 ℃ (275 °F) for 8 hours, and up to 150 ℃ (300 °F) for 1 hour peak exposure.
    Q What is the cable's breaking strength and recommended working tension?
    The cable has a total breaking strength of 30 kN (6,700 lbs). The maximum suggested working tension is 15 kN (3,350 lbs), which is 50% of the breaking strength — ensuring a reliable safety margin during downhole operations.
    Q What voltage rating and insulation resistance does this cable offer?
    The cable carries a voltage rating of 1200 VDC. Its insulation resistance is exceptionally high at 15,000 MΩ·km (50,000 MΩ·kft), making it suitable for demanding electrical logging and measurement applications.
    Q What are the armor wire specifications and their breaking strengths?
    The inner armor consists of 15 wires at 0.61 mm (0.0240") diameter, with an average wire breaking strength of 600 N (135 lbs). The outer armor uses 15 wires at 0.89 mm (0.0350") diameter, with each wire rated at 1,300 N (292 lbs) breaking strength.
    Q What is the minimum sheave diameter recommended for this cable?
    The minimum sheave (pulley) diameter recommended for safe operation is 320 mm (13"). Using a sheave smaller than this may cause excessive bending stress, reducing the cable's service life and mechanical integrity.
    Q What is the conductor construction and electrical resistance of this cable?
    The conductor uses a 19-strand copper construction with each strand measuring 0.30 mm (0.0118") in diameter, providing excellent flexibility and conductivity. The typical DC resistance at 20 ℃ is 13.1 Ω/km (4.0 Ω/kft), suitable for low-loss signal and power transmission.