Leave Your Message
Single-Conductor Logging Cable G1FB-6.35 - 316L/825 Armor, 16 AWG TEC Cable from China Suppliers and Factory
Hot Products

Single-Conductor Logging Cable G1FB-6.35 - 316L/825 Armor, 16 AWG TEC Cable from China Suppliers and Factory

Introducing the G1FB-6.35 Logging Cable, a premium quality single-conductor cable designed for heavy-duty applications. With an outer diameter of 6.35 mm, this cable features a robust copper conductor and advanced fluoroplastic insulation, ensuring optimal performance in various environments. Its seamless steel pipe armor provides exceptional protection against harsh conditions, making it waterproof and sealed, Engineered for medium to deep well logging, the G1FB-6.35 is ideal for conventional oil and gas exploration and production. With high tensile strength and excellent rigidity, this logging cable is an essential choice for companies seeking reliable solutions. As a leading product from China, we pride ourselves on being top Suppliers and a trusted Factory, dedicated to delivering high-quality logging cables that meet industry standards. Upgrade your logging equipment with the reliable G1FB-6.35 Logging Cable today!

    Construction
    Copper Construction 1×1.24 mm 1×0.0488″
    Insulation F 1.80 mm 0.0709″
    Protection PP 4.76 mm 0.1874″
    Armor 6.35 mm 0.25″
    Physical
    Cable Diameter 6.35 mm ± 0.10 mm 0.25″ ± 0.0039″
    Cable Weight in Air 167 kg/km 112 lbs/kft
    Cont. Temp Rating 150 ℃ 300 ℉
    Mechanical
    Cable Breaking Strength 10 kN 2250 lbs
    Max. Suggested Working Tension 5 kN 1125 lbs
    Min. Shave Diameter 800 mm 31.5″
    Electrical
    Voltage Rating 1000 VDC 1000 VDC
    Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
    Resistance Typical 18.1 Ω/km 5.5 Ω/kft
    Capacitance@1kHz 92 pf/m 28 pf/ft
    Frequently Asked Questions
    Q What is the maximum continuous temperature rating for this cable?
    This cable has a continuous temperature rating of 150°C (300°F), making it suitable for high-temperature downhole and industrial environments where thermal performance is critical.
    Q What is the voltage rating of this cable?
    The cable is rated at 1000 VDC, suitable for direct-current applications requiring reliable insulation performance under sustained electrical load conditions.
    Q What is the cable breaking strength and recommended working tension?
    The cable has a breaking strength of 10 kN (2250 lbs). The maximum suggested working tension is 5 kN (1125 lbs), which is 50% of the breaking strength to ensure a safe operating margin during deployment.
    Q What are the outer diameter and weight specifications of the cable?
    The armored cable has an outer diameter of 6.35 mm (0.25″) with a tolerance of ±0.10 mm. It weighs approximately 167 kg/km (112 lbs/kft) in air, making it a compact and lightweight solution for logging and monitoring applications.
    Q What is the minimum shave diameter requirement for this cable?
    The minimum shave (sheave) diameter for this cable is 800 mm (31.5″). Using a sheave smaller than this may cause mechanical fatigue or damage to the cable structure over repeated spooling cycles.
    Q What are the insulation resistance and capacitance values of this cable?
    The cable offers an insulation resistance of 15,000 MΩ·km (50,000 MΩ·kft), ensuring excellent electrical isolation. The capacitance at 1 kHz is 92 pF/m (28 pF/ft), which is important for signal integrity in logging and telemetry applications.