Leave Your Message
China 5/16 8.0 mm 3-Conductor Cable Suppliers - AWG 20 with Copper Conductor and FEP Insulation from Factory
Hot Products

China 5/16 8.0 mm 3-Conductor Cable Suppliers - AWG 20 with Copper Conductor and FEP Insulation from Factory

,

5/16  8.0 mm

,

3-CONDUCTOR, AWG 20 

,

Copper  High-Quality Copper Conductor for Enhanced Performance

,

FEP   Premium FEP Insulation for Superior Heat Resistance

,

Semi-conducting   Semi-conducting Filler for Improved Signal Integrity

,

Semi-conducting   Robust Semi-conducting Shield Layer for Enhanced Protection

,

Inner  Inner Armor Wires Ensuring Durability and Resilience

,

Outer  Outer Armor Wires Providing Additional Layer of Strength

,

As a leading manufacturer in China, our factory specializes in producing top-quality electrical conductors. Partner with reputable suppliers to ensure you receive products that meet the highest standards of performance and safety. Our commitment to excellence guarantees that you benefit from reliable and efficient electrical solutions.

,

    Construction
    Copper Construction 7×0.32 mm 7×0.0129"
    Insulation (FEP) 1.86 mm 0.0732"
    Number and Size of Wires
    Inner Armor 18×0.81 mm 18×0.0319"
    Outer Armor 18×1.11 mm 18×0.0437"
    Average Wire Breaking Strength
    Inner Armor 963 N 216 lbs
    Outer Armor 1808 N 406 lbs
    Physical
    Cable Diameter 8.0 mm +0.13 mm / −0.05 mm 0.3150" +0.0051" / −0.0019"
    Cable Weight in Air 265 g/km 175 lbs/kft
    1 hr. Max Temp 232 ℃ 450 °F
    8 hr. Max Temp 216 ℃ 421 °F
    Cont. Max Temp 200 ℃ 392 °F
    Mechanical
    Cable Breaking Strength 45 kN 10,100 lbs
    Maximum Suggested Working Tension 22.5 kN 5,050 lbs
    Minimum Shave Diameter 450 mm 18"
    Cable Stretch Coefficient 1.35 m/km/5kN 1.2 ft/kft/klbs
    Electrical
    Voltage Rating 1000 VDC 1000 VDC
    Insulation Resistance 15,000 MΩ·km 50,000 MΩ·kft
    Resistance Typical @ 20 ℃ 33 Ω/km 10 Ω/kft
    Capacitance @ 1kHz 175 pF/m 53 pF/ft
    ? Frequently Asked Questions
    Q What type of insulation material is used in this cable?
    A This cable uses FEP (Fluorinated Ethylene Propylene) insulation with an outer diameter of 1.86 mm (0.0732"). FEP is chosen for its excellent thermal resistance, low dielectric constant, and chemical inertness — making it highly suitable for high-temperature downhole environments.
    Q What is the maximum continuous operating temperature of this cable?
    A The cable is rated at a continuous maximum temperature of 200 ℃ (392 °F). For short-term exposure, it can handle up to 232 ℃ (450 °F) for 1 hour, or 216 ℃ (421 °F) for 8 hours.
    Q What is the cable breaking strength and recommended working tension?
    A The cable has a breaking strength of 45 kN (10,100 lbs). The maximum suggested working tension is 22.5 kN (5,050 lbs), which is 50% of the breaking strength — following standard safety practice for wireline and downhole cable operations.
    Q What is the voltage rating and insulation resistance of the cable?
    A The cable is rated at 1000 VDC. Its insulation resistance is 15,000 MΩ·km (50,000 MΩ·kft), indicating extremely high electrical isolation, which is critical for accurate signal transmission in logging and telemetry applications.
    Q What is the minimum shave (sheave) diameter required for this cable?
    A The minimum sheave diameter is 450 mm (18"). Using a sheave smaller than this minimum may cause excessive bending stress on the armor wires, reducing cable lifespan or leading to premature mechanical failure.
    Q How is the dual-armor construction beneficial compared to single-armor cable?
    A The dual-armor design — with an inner armor (18×0.81 mm, 963 N per wire) and an outer armor (18×1.11 mm, 1808 N per wire) — provides superior tensile strength, abrasion resistance, and protection against wellbore pressure and mechanical damage, making it ideal for deep well and high-tension deployment applications.