Leave Your Message
GX-GG-2B1-2A1a-4.0  ( 0.157”), 4.0mm, 2 SM+2 MM, Optical Fiber
Fiber Optic Cable
Products Categories
Featured Products

GX-GG-2B1-2A1a-4.0 ( 0.157”), 4.0mm, 2 SM+2 MM, Optical Fiber

This is an optical fiber logging cable with a structure of 2B1 single-mode fiber and 2A1a multi-mode fiber, totaling 4 fibers, and an outer diameter of 3.2 mm. Used for DTS, DAS, DVS, High SpeedData Transmission, Real Time Monitoringwhile well intervention, VSP.

    Applicable Well Types:

    1.Conventional Oil & Gas Wells

    Adaptable Well Types: Medium-shallow vertical wells (depth ≤ 3000m), low-deviation directional wells (build-up section ≤ 50°), shallow to medium-depth cased wells (φ89mm/φ114mm casing), open-hole exploration wells

    Typical Applications: Daily monitoring of conventional production wells, supplementary logging of old wells, exploration logging of shallow to medium-depth oil & gas fields, production dynamic monitoring of cased wells

    2. Unconventional Oil & Gas Wells

    Adaptable Well Types:Shallow to medium-depth coalbed methane (CBM) wells (depth ≤ 2500m), shallow shale gas vertical wells, low-cost development wells for tight oil & gas

    Typical Applications: CBM well production monitoring, shale gas exploration stage logging, tight oil & gas reservoir monitoring, environmental monitoring of unconventional well sites

    3. Other Exploration & Engineering Wells

    Adaptable Well Types: Shallow geothermal wells (bottomhole temperature ≤ 150℃, depth ≤ 2500m), hydrogeological exploration wells, small-diameter monitoring wells in underground coal mines, shallow water injection wells

    Typical Applications:Temperature monitoring of shallow geothermal development, groundwater level and quality monitoring, coal mine underground gas concentration monitoring, water injection profile monitoring of water injection wells

    Strictly Inapplicable Scenarios

    1.Deep/ultra-deep wells (depth > 3000m): 7kN breaking strength cannot withstand the total tension from the cable's own weight + logging tool weight, leading to high risk of cable breakage.

    2.High-deviation wells (> 50°)/long-horizontal-section horizontal wells (horizontal section > 800m): Insufficient torsion and wear resistance; prone to cable sticking, wrapping or excessive wear in high-curvature or long-distance horizontal sections.

    3.Ultra-high temperature wells (bottomhole temperature > 150℃): Exceeding the rated temperature causes aging of the insulation layer and increased fiber signal attenuation, resulting in monitoring failure.

    4.Highly corrosive wells (high H₂S/CO₂ content): Lack of special anti-corrosion coating, conventional 316L stainless steel cannot long-term resist strong corrosive media, leading to armor rust and fiber damage.

    5.Ultra-high pressure wells (well pressure > 70MPa): Exceeding the rated pressure of the cable, risking seal failure and structural damage.

    6.Short-radius horizontal wells (build-up rate > 12°/100ft): Minimum bending diameter (600mm) cannot adapt to high build-up rate trajectories, easily causing fiber breakage.

    Selection Reference

    Parameter

    Specification

    Applicable Well Condition

    Typical Well Type

    Fiber Configuration

    2 single-mode (B1) + 2 multi-mode (A1a), 316L stainless steel fiber unit tube

    DTS/DAS signal transmission, bottomhole temperature ≤150℃, no heavy mechanical load, fiber reserve length >3‰

    Conventional oil & gas wells, coalbed methane wells, geothermal wells

    Temperature Resistance

    Rated temperature 150℃ (302℉), FEP inner protective layer, stable performance at medium temperature

    Medium-temperature working conditions, bottomhole temperature ≤150℃, no ultra-high temperature (>150℃) environment

    Medium-shallow conventional oil & gas wells, shallow geothermal wells, coal mine underground monitoring wells

    Protection & Outer Diameter

    Outer diameter 4.0mm±0.10mm, 316L stainless steel outer tube + FEP encapsulation, corrosion-resistant

    Wellbore diameter ≥100mm, moderate wellbore wear, weak to medium corrosive formation fluid (low H₂S/CO₂ content), rated pressure ≤70MPa

    Shallow to medium-depth cased wells, open-hole exploration wells, small-diameter monitoring wells

    Mechanical Performance

    Breaking strength 7kN, maximum working tension 3.5kN, minimum bending diameter 600mm, good flexibility

    Well depth ≤3000m, build-up section ≤50°, no sudden dogleg severity, horizontal section ≤800m (long radius)

    Medium-shallow vertical wells, low-deviation directional wells, shallow shale gas vertical wells

    Send Inquiry