WGSB-5.6 MONOCONDUCTOR ( 7/32" ) AWG 17 Wireline Logging Cable
Core Applicable Well Types and Operation Scenarios
1. Conventional Logging Operations in Onshore Medium-Deep Wells
Applicable Conditions: Straight or directional wells with a build rate ≤ 30°, well depth 2000–6000m, continuous downhole temperature ≤ 135℃ (short-term up to 150℃), neutral fluid environment (no H₂S/CO₂ corrosion), and regular wellbore trajectories.
Suitable Operations: Routine logging of open hole/cased holes (acquisition of resistivity, sonic, density, etc.), production dynamic monitoring, and basic logging evaluation after completion.
2. Perforation and Coring Operations in Oil & Gas Wells
Applicable Conditions: Perforation construction in medium-deep wells (without extreme high-temperature and high-pressure conditions), conventional core coring operations, moderate friction resistance in wellbore, and no severe scaling/restriction.
Suitable Operations: Coordinate with perforating guns for perforation in medium-deep wells, and complete signal transmission and depth control during core coring, meeting the needs of mechanical load-bearing and power supply.
3. Low-Risk Old Well Recommissioning and Simple Workover
Applicable Conditions: Mature old wells with only slight scaling and minor wellbore constriction, downhole temperature ≤ 135℃, and no acidic corrosion. Workover operations focus on basic detection and simple modification.
Suitable Operations: Casing integrity testing of old wells, auxiliary scraping operations, and basic logging verification before recommissioning. Compatible with light-duty workover tools and single-core monitoring equipment.
4. Onshore Conventional Exploration Wells and Geological Monitoring
Applicable Conditions: Onshore shallow to medium-deep exploration wells and coalfield geological survey wells with stable formation temperature and pressure, no corrosive media, and no high-curvature horizontal sections in wellbore.
Suitable Operations: Initial formation evaluation, single-parameter logging after drilling and completion, and geological dynamic monitoring, meeting the needs of low-cost, stable transmission for batch exploration wells.
Strictly Inapplicable Scenarios
1. High-Temperature Wells (continuous temperature > 150℃) and Ultra-Deep Wells.
2. Sulfur-Containing/Acid-Corrosive Wells (H₂S/CO₂ environment).
3. High-Curvature Horizontal Wells (curvature radius < 300m) and Wells with Severe Friction/Scaling.
4. Geothermal Wells, High-Pressure Well Testing, and Heavy Oil Wells.
5. Offshore Oil & Gas Wells and High-Salt Spray Environments.
Selection Reference
Technical Parameter |
Specification |
Applicable Well Condition |
Typical Applied Well Type |
Insulation |
Polypropylene (PP) |
Max continuous temperature resistance 150°C, neutral fluid environment |
conventional medium-deep well temperature and pressure conditions |
Cable Breaking Strength |
25kN 12.5lbs |
Support the conventional tensile load of medium-deep wells within 6000ms |
Conventional lifting and dragging operations in medium-deep wells |
Armor |
High-tensile galvanized steel |
Non-corrosive, moderate friction, conventional tension/bending |
Improve tensile and wear resistance, meeting the dragging requirements of medium-deep wells |
Minimum Sheave Diameter |
13″ 320mm |
Standard on-site logging winches/operation equipment in oilfields |
All applicable well types |
Send Inquiry